Skip to content
  • Land / Pays / Country
    • België (Nederlands)
    • Belgique (Français)
    • France
    • Nederland
    • Other countries (English)
  • Land / Pays / Country
    • België (Nederlands)
    • Belgique (Français)
    • France
    • Nederland
    • Other countries (English)
  • NL
  • FR
  • EN
  • Land / Pays / Country
    • België (Nederlands)
    • Belgique (Français)
    • France
    • Nederland
    • Other countries (English)
  • Land / Pays / Country
    • België (Nederlands)
    • Belgique (Français)
    • France
    • Nederland
    • Other countries (English)
  • NL
  • FR
  • EN
Icomet group
Contact
  • Home
  • Metal Quartz
    • High security joinery
  • Bunkerkit
    • Armored modular rooms and walls
  • Stackdoor
    • Security stacking fences
  • Performances
  • Home
  • Metal Quartz
    • High security joinery
  • Bunkerkit
    • Armored modular rooms and walls
  • Stackdoor
    • Security stacking fences
  • Performances
Icomet group
Contact
  • Home
  • Metal Quartz
    • High security joinery
  • Bunkerkit
    • Armored modular rooms and walls
  • Stackdoor
    • Security stacking fences
  • Performances
    brandwerend

    Fire resistant

    inbraakwerend

    Burglar-resistant

    kogelwerend

    Bulletproof

    elektromagnetische straling

    Anti electromagnetic radiation

    geluidwerend

    Soundproof

    explosiebestendig

    Explosion proof

    anti-paniek

    Anti-panic

    gevangenissen

    Prisons

    isotherm

    Isothermal / Cold stores

    luchtdicht

    Airtight

    rookdicht

    Smoke-tight

    thermisch geïsoleerd

    Thermal insulation

    waterdicht

    Watertight

    winddicht

    Windproof

Home > Prestaties > Thermal insulation

thermisch geïsoleerd

Thermal insulation

EN 10077-1 & EN 10077-2 : T0, T1, T2, T3, T4, T5

Doors, gates and windows often have to be thermally insulated when they are placed as a partition in rooms where a functional temperature is desirable or necessary. This can be e.g. interior doors as well as exterior doors.

In Belgium, the standards are becoming stricter. For example, the maximum heat losses for doors should not exceed 2.0 W/m² and 1.5 W/m² for windows.

To be considered thermally insulating, the U-value of the door must be ≤ 3.5 W/m²K and guarantee a minimum air-tightness (at least class L2).

The thermally insulated doors, gates and windows supplied by us meet the U-values T0 to T5, depending on the desired version.

For doors and gates for cold stores and freezers, we refer to our applications with isothermal properties.

A specific question? Would you like more information or a quote?

Thanks to our many years of experience, we can quickly develop the right solution for all metal constructions, steel doors and automation of entrances.

Request more information or a free quote

Types of performances

brandwerend
inbraakwerend
geluidwerend
kogelwerend
explosiebestendig
elektromagnetische straling
gevangenissen
anti-paniek
rookdicht
thermisch geïsoleerd
luchtdicht
waterdicht
winddicht
isotherm

ICOMET GROUP - your certified partner

ICOMET GROUP proves time and again that we take all constructions and installations very seriously by meeting the required standards and obtaining the necessary certificates. We are therefore the most suitable partner for carrying out all your industrial entrances and metal constructions.

thumbnail_image001

ICOMET GROUP

  • Industriezone IZ8
    Filliersdreef 20
    9800 Deinze
    Belgium
  • info@icometgroup.com
  • +32 (0)9 330 05 47
  • VAT-number
    BE0755965837
Contact
Also visit the specialized websites of our subsidiaries
  • METALQUARTZ
  • BUNKERKIT
  • STACKDOOR
© ICOMET GROUP – Privacy Policy
Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}